desktop large-capacity centrifuge

產(chǎn)品簡(jiǎn)介

SG-851-type desktop large-capacity electric centrifuge is the company to meet the needs of various laboratories, carefully designed and sophisticated process technology

產(chǎn)品型號(hào):SG-851-type
更新時(shí)間:2019-05-05
廠商性質(zhì):生產(chǎn)廠家
訪問(wèn)量:3810
詳細(xì)介紹在線留言

SG-851-type desktop large-capacity electric centrifuge is the company to meet the needs of various laboratories, carefully designed and sophisticated process technology, large capacity for various types of laboratory experiments by centrifugation of precision instruments。
This high-speed centrifuges used centrifuge rotor rotating centrifugal force generated by the powerful, to speed up the settling velocity of particles in the liquid, the samples of different sedimentation coefficient and buoyant density of the material separate, is a non-uniform system of liquid separation equipment.

Features:
1, attractive appearance, small size, fully functional
2, light weight, large capacity
3, simple, easy to use
4, stable, adjustable speed and can automatically adjust the balance
5, low temperature rise of high efficiency, wide adaptability
6, applies to the hospital laboratory, biochemistry laboratory for qualitative analysis, for plasma, serum, urea, and vaccine manufacturing use.

Technical data:

1, time range 0-60
2, rated power: 200W
3, speed range :500-6000 r / min
4, centrifugal Capacity: 50ml * 6
5, the centrifugal force: 7250g
6, Dimensions (mm): length * width * height 380 * 280 *270

Handling Precautions
Work in a high speed centrifuge, used to safety and to ensure that the equipment to maintain high precision work, we must do the following:
(1).Centrifuges used to be placed in a smooth, strong on the counter; large-capacity high-speed low-speed centrifuge and refrigerated centrifuge to be placed accordingly on the ground in a solid, level place. Centrifuge work done, the load balancing, weight error as small as possible, otherwise it will cause severe vibration, and shaft damage turned centrifuge.
(2).Centrifuge starts, switch knob should be on the low speed position, start and then gradually adjust to the desired value. A work, shall knob again transferred to low-bit work, at high speed block ban on direct start.
(3).Rotor in the strict inspection before each use if a foreign body and the dirt hole, in order to maintain balance. Turned around and must be kept dry and clean, do not impact abrasion. Such as accidentally dropped, turned to X-ray film should check that no internal injury can continue to use. Turned after each use with warm water (50 ℃ ~ 60 ℃) and neutral detergent immersion cleaning, and finally with distilled or deionized water rinse, soft cloth after drying with hair dryer, wax, dry place.
(4).Pull all kinds of tube length, strength and stretch are different, should the need to use, the tube can be made of many different materials, such as polyethylene, cellulose, polycarbonates, polypropylene. Use care to ensure the sample, non-corrosive materials, solvent and gradient centrifuge tube and cap components. Expired, the aging, there are cracks or corrosion of the tube by minimizing or spin-down use. Control the use of plastic tube number, pay attention to standard matching. Centrifugal process may open the centrifuge lid, not by hand or foreign body collisions are turned and the rotation of the centrifuge tube.
(5) To ensure safety, be sure to use ground wire
(6).In the centrifuge process, such as abnormal phenomena, such as the noise and vibration is not normal, should immediay stop checks, not to find reasons not to continue to operate .
(7).Daily use of centrifuges in the process, every three months the level of response to host a degree of correction for each transfer using 500 million deal with a vacuum pump oil, working 500h should check drive motor carbon brush, preferably with a vacuum cleaner to friction toner remove, if necessary, to replace carbon brushes or commutator with fine sandpaper polish.Should be cleaned about every driver using the 1500h site with high-speed bearings and grease shaft and turned rust-proof joint of fat should be kept painted, do not be long-term anti-rust oil coating oil paper wrap. When not in use should be switched each month low 1 or 2 times, each time 0.5h, to ensure the normal operation of the site.
(8). Be sure to place the centrifuge tube placed symmetrically, and to keep the weight fairly. Things in the open centrifuge to centrifuge lid.
(9). Centrifugal liquid should not be too low boiling point,Should pay attention to internal and external pressure ratio.If it is toxic reagents, but also good ventilation treatment.
 

在線留言

留言框

  • 產(chǎn)品:

  • 您的單位:

  • 您的姓名:

  • 聯(lián)系電話:

  • 常用郵箱:

  • 省份:

  • 詳細(xì)地址:

  • 補(bǔ)充說(shuō)明:

  • 驗(yàn)證碼:

    請(qǐng)輸入計(jì)算結(jié)果(填寫(xiě)阿拉伯?dāng)?shù)字),如:三加四=7

掃碼加微信,了解最新動(dòng)態(tài)

掃碼加微信
021-65682142

Copyright © 2025 上海碩光電子科技有限公司版權(quán)所有

技術(shù)支持:化工儀器網(wǎng)    sitemap.xml

滬公網(wǎng)安備 31011002005640號(hào)

久久久国产精品免费中文| 国产探花在线精品一区二区| 无码日韩精品一区二区人妻| 久久久久噜噜噜亚洲熟女综合| 中文无码人妻在线一区不卡 | a级毛片无码专区免费看| 波多野结衣av| 国精产品999永久中国有限公司| 青楼男妓h高潮啊哈男男| 亚洲欧美人成综合在线另 | 又粗又深又猛又爽的视频| 久久亚洲AV成人无码国产| 野花免费观看高清在线4| 自拍不卡dvd在线一区| 99久久人妻精品免费三区| 成人在线免费电影| 狠狠色噜噜狠狠狠狠AV不卡| 白乳房天天官网性插视频| 亚洲精品久久久久久一区| 中文字幕在线亚洲精品| 精品丰满人妻无套内射| 久久综合AV色老头免费观看| 国产成人第一页在线视频| 性色av久久av达盖尔| 色婷婷樱桃Av一区二区| 少妇高潮久久久久久久久| 国产超碰人人做人人爱ⅴa| 亚洲区色情区激情区小说| rh男男车车的车车视频软件| 噜噜噜久久亚洲精品国产| 精华欧美一区二区久久久| 欧洲中字中文字幕第一区| 我的少妇邻居全文免费| 强行糟蹋人妻hd中文字幕| 99九九免费线视频精品| 欧美国产成人精品一区二区三区| 欧洲精品视频完整版在线| 男人操亚洲美女| 人妻少妇久久久久久97人妻| 最猛性xxxxx亚洲精品| 成人毛片一区二区|